CE-6000 Pack Tester
200V~1000V, 100A~1500A
CE-6000 series pack tester, as the new generation testing system with high voltage voltage and high power output capability, is designed for the tests of battery pack.
CE-6000 series pack tester utilizes IGBT (Insulated Gate Bipolar Transistor) technology which is much different from traditional power deivices and control methods. Stable and reliable testing control performance makes CE-6000 the best system for EV battery and energy storge battery.
Voltage/Current Accuracy
±0.05%F.S.
Recording
100Hz
Current Switch Time
≤20ms
Current Respond Time
≤10ms
Min. Pulse Width/ Simulation
100ms
Regenerative/ Parallel
96%(MAX)/ Supported
Features
- Focus on high power pack level testing plateform
- Ultra range for current test
- Combined with 24-bit ADC analog-to-digital conversion chip
- DC/AC and DC/DC are independent. DC/AC adopts SVPWM modulation technology, and the PID feedforward control algorithm ensures the energy balance of DC/DC under complex working conditions.
- Independent electric reactor
- Constant power model supported
- Operated on HMI
- Support CAN/ RS485 communication
- Max. 4 channels parallel support
- Ethernet control method
- Human-computer interaction interface
Typical Model
Models | Voltage | Current | Channels | Specification |
---|---|---|---|---|
CE-6016n-30V30A-H | 30V | 30A | 16CH | |
CE-6016n-30V100A-H | 30V | 100A | 16CH | |
CE-6016n-60V100A-H | 60V | 100A | 16CH | |
CE-6004n-60V600A-H | 60V | 600A | 4CH | |
CE-6016n-100V100A-H | 100V | 100A | 16CH | |
CE-6012n-120V100A-H | 120V | 100A | 12CH | |
CE-6005n-200V200A-H | 200V | 200A | 5CH | |
CE-6003n-200V500A-H | 200V | 500A | 3CH | |
CE-6002n-60V1200A-H | 60V | 1200A | 2CH | |
... | ... | ... | ... |
*Model for reference, please contact us to get the update spec.
208VAC/ 408VAC/ 480V optional with transformer can be provided for different grid required user.
Individual charge/discharge port supported.
Contact us to get more information~
Parallel Functions in Module

System Safety Protection
- Grid Over/Under-Voltage Protection
- AC Short-Circuit and Phase Loss Protection
- Over-Voltage/Over-Current Output Protection
- Overheating Protection
- Open/Short Circuit Protection
- Emergency Stop Protection
- Self-Diagnosis Protection
- Redundant Voltage Channels Protection
- DC Polarity Reverse Protection
- Power-Off Resumption Protection
- Grid Voltage Phase and Frequency Adaptive
- Adjustable Protection Values for Voltage and Current
- Traceable Protection Log

Regenerative Flow
While discharge, the discharge energy will be consumed to other charge channels, while it has rest energy, the energy will be convert and back to the internal grid system by AC-DC module.

CAN/ RS485 Communication Support
Build-in CAN/RS485 edit interface in BTS software. Easy programme the script in Neware powerful software.

Enable communication with third-party equipment
Third-party Test Chamber, Water-cooling Machine, External Pressure fixture, External Aux Temperature Machine, etc.
Try with Neware Aux Temperature System