8 channels——18650 battery tester cycle life test, charge and discharge test,
cycle life test, DCIR test, pulse test.
we only export and supply excellent quality Battery Charging Station, which is widely used all over the world.
The similar model like this one include: 5V3A,5V6A,10V6A,10V10A,10V20A,20V3A,20V6A,etc.
This equipment is 8 channels per set, and 10 sets for one rack, 80 channels.
Battery type can be tester: pack tester for Li-ion, LiFePO4, Ni-MH, Ni-CD and lead acid battery.
Items can be tested:
Current, voltage, power, DCIR,capacity, cycle test, Pulse test, etc
Reliable hardware with independent constant current and voltage control.
18650 battery tester cycle life test Features:
1)According to the international standard design, each channel of the system has an independent constant-current source and a hardware constant-voltage source which make system stable & reliable
2)Modular design leads to easy maintain
3)Different holder selectable, satisfy your different needs
4)Efficient heat dissipation system, ensure proper working of equipments under 24hrs full load condition
5)Double loop-control adopted,no peak occured from CC to CV, protect the battery
18650 battery tester cycle life test Software Features
1)Each channel available for indepent program testing,Step continuable after Pause in any
conditions(including blackout)
2)Host computer adaptable to all kinds of lower machine,with interactive interface,easy to
operate
3)Fast data acquisition,sensitive to the changing of current & voltage,(AD ,16bit),dairy function
available
4)Powerful for data and chart processing ,support four types of report with various form formats
5)As an added bonus,professional tool software would be provided free of charge, including
accurancy correction software for current & voltage .CTN No.& measuring range changable.
Battery Charging Station 5V6A Tesing System Specification:
BTS-5V6A |
Battery Testing System |
||||||||||
Description |
Product Specification |
||||||||||
AC Input |
AC 220V±10% 50Hz |
||||||||||
Power |
213 |
W |
|||||||||
Resolution |
AD: 16bit; DA: 12bit |
||||||||||
Input Impedance |
≥1MΩ |
||||||||||
Voltage |
Measuring Range |
Charge:25mV~5V |
Discharge: 25mV~5V |
||||||||
Discharge Min Voltage |
1.5V |
||||||||||
Accuracy |
± 0.1% of FS |
||||||||||
Stability |
± 0.1% of FS |
||||||||||
Current |
Range |
Range1:0.5mA~100mA Range2:100mA~6A |
|||||||||
Accuracy |
± 0.05% of FS |
||||||||||
Stability |
± 0.1% of FS |
||||||||||
Power |
Output Power Per Channel |
15W |
|||||||||
Stability |
± 0.1% of FS |
||||||||||
Time |
Rise Time |
20ms (0~Full Range) |
|||||||||
Step Time |
≤ (365*24) hour/step |
Time Format 00:00:00 (h:min:s) |
|||||||||
Data Acquisition |
Intervals |
Time interval Δt:(1s~60000s) |
|||||||||
Voltage interval ΔU: (10mV~5V) |
|||||||||||
Current interval ΔI: (Range1:0.2mA;Range2:12mA) |
|||||||||||
Frequency |
10Hz |
||||||||||
Charge |
Mode of Operation |
CCC, CVC, CC & CVC |
|||||||||
End Conditions |
Voltage, Current, Test Time, Capacity |
||||||||||
Discharge |
Mode of Operation |
CCD, CPD |
|||||||||
End Conditions |
Voltage, Current, Test Time, Capacity |
||||||||||
Cycle |
Cycles |
65535 |
|||||||||
Steps |
254 |
||||||||||
Nested Function |
Max three levels of loops |
||||||||||
Protective Function |
Software |
● Power-off data protection |
|||||||||
● User-defined safety(upper and lower)tolerance of current, voltage and delay time |
****Different Specifications could be customized ,Ranging from 1mA-3000A, 5-800V;)****
If you are interested in NEWARE battery testing equipment, pls contact us !
Download the 5V6A-18650 Battery Tester Cycle Life Test Specification!!