BTS-8004-5V200A Driving Cycle Simulation Specification:
BTS-5V200A Battery Testing System Driving Cycle Simulation
|
|||
Model:BTS-5V200A |
Material Code:CT-8004-5V200A |
||
Description |
Product Specification |
||
AC Input |
AC 380V±10% 50Hz |
||
Power |
7089 |
W |
|
Resolution |
AD: 16bit; DA: 16bit |
||
Input Impedance |
≥1MΩ |
||
Voltage |
Measuring Range |
Charge: 25mV~5V Discharge: 25mV~5V |
|
|
Discharge Min Voltage |
2.5V |
|
|
Accuracy |
± 0.1% of FS |
|
|
Stability |
± 0.1% of FS |
|
Current |
Range |
1A~200A |
|
|
Accuracy |
± 0.1% of FS |
|
|
Stability |
± 0.1% of FS |
|
Power |
Output Power Per Channel |
1000W |
|
|
Stability |
± 0.2% of FS |
|
Time |
Rise Time |
20ms (0~Full Range) |
|
|
Step Time |
≤ (365*24) hour/step
Time Format 00:00:00:000 (h:min:s:ms) |
|
Data Acquisition |
Intervals |
Time interval Δt: 10ms |
|
Voltage interval ΔU: 10mV |
|||
Current interval ΔI: 400mA~6A |
|||
|
Frequency |
100Hz |
|
Charge |
Mode of Operation |
CCC, CVC, CC & CVC, CPC, Simulation |
|
|
End Conditions |
Voltage, Current, Test Time, Capacity |
|
Discharge |
Mode of Operation |
CCD, CPD, CRD |
|
|
End Conditions |
Voltage, Current, Test Time, Capacity |
|
Pulse mode |
Charge |
CR mode、CP mode |
|
|
Discharge |
CC mode、CP mode |
|
|
Min pulse width |
500ms |
|
|
Automated Switch |
Automated switch from charge to discharge for each pulse |
|
|
End Condition |
Voltage、Relative Time |
|
Simulation |
Charge Mode |
Current, power |
|
|
Discharge Mode |
Current, power |
|
|
End Condition |
Time, line number |
|
|
Charge and discharge continuous switching |
A simulation step can be achieved from the charging to the discharge of continuous switching |
|
|
Limit the number of line files |
100,000 |
|
DCIR |
Support for the calculation of the point of the DCIR |
||
Parallel mode |
Up to 2 channels can be supported in parallel, and impulse and condition simulation are not supported after parallel connection |
||
Cycle |
Cycles |
65535 |
|
Steps |
254 |
||
Nested Function |
Max three levels of loops |
||
Protective Function |
● Power-off data protection |
||
● Off-line Operating |
|||
● User-defined safety(upper and lower)tolerance of current, voltage and delay time |
|||
● With anti-reverse function |
|||
Channel Features |
Independent pairs of closed loop for constant current source and constant voltage source |
||
Channels |
Independent control |
||
Detection and Sampling |
4-wire Connecting |
||
Noise Density |
<85dB |
||
Data Management |
MYSQL Database |
||
Communication Means |
TCP/IP Protocol |
||
Export Formats |
EXCEL2003/2010, TXT, Graph |
||
Communication Interface |
Ethernet Port |
||
Number of Channels Per Cabinet |
4 |
||
Operating Environment |
|||
Description |
Product Specification |
||
Operating Temperature |
0℃~40℃(In the 25 ± 10 ℃ range, to ensure accuracy: Accuracy drift 0.005% of FS / ℃) |
||
Storage Temperature |
-10℃~50℃ |
||
Operating Humidity |
≤70% RH |
||
Storage Humidity |
≤80% RH |
||
Description |
Product Specification |
||
Battery Holder |
Universal Holder |
||
Holder Picture |
Depends on customer requirment |
||
Dimensions (W*D*H)(mm) |
30U(19),600*600*1520 (Just for reference) |
||
Need help? Contact us!