This is CT-4008-5V6A-S1 Technology Specification
BTS-5V6A Battery Testing System For cylinder/pouch cell |
||||
Model: BTS--4008-5V6A
|
||||
Description |
Product Specification |
|||
AC Input |
AC 220V±10% 50Hz (AC110V,60Hz can be customized) |
|||
Power |
425W |
|||
Resolution |
AD: 16bit; DA: 16bit |
|||
Input Impedance |
≥1MΩ |
|||
Voltage |
Measuring Range |
Charge: 25mV~5V |
Discharge: 25mV~5V |
|
|
Discharge Min Voltage |
1.2V |
||
|
Accuracy |
± 0.05% of FS |
||
|
Stability |
± 0.05% of FS |
||
Current |
Range |
Range1: 0.5mA~0.1A Range2: 0.1A~3A Range3: 3A~6A |
||
|
Accuracy |
± 0.05% of FS |
||
|
Stability |
± 0.05% of FS |
||
|
Constant Voltage stop current |
Range1: 0.2mA; Range2: 6mA; Range3: 12mA |
||
Power |
Output Power Per Channel |
30W |
||
|
Stability |
± 0.1% of FS |
||
Time |
Rise Time |
1ms (0~Full Range) |
||
|
Step Time |
≤ (365*24) hour/step |
Time Format 00:00:00:000 (h:min:s:ms) |
|
Data Acquisition |
Intervals |
Time interval Δt:(100ms~60000s) |
||
|
|
Voltage interval ΔU: (10mV~5V) |
||
|
|
Current interval ΔI: (Range1: 0.2mA; Range2: 6mA; Range3: 12mA) |
||
|
Frequency |
10Hz |
||
Charge |
Mode of Operation |
CCC, CVC, CC & CVC, CPC |
||
|
End Conditions |
Voltage, Current, Test Time, Capacity |
||
Discharge |
Mode of Operation |
CCD, CPD, CRD |
||
|
End Conditions |
Voltage, Current, Test Time, Capacity |
||
Pulse mode |
Charge |
CR mode、CP mode |
||
|
Discharge |
CC mode、CP mode |
||
|
Min pulse width |
500ms |
||
|
Automated Switch |
Automated switch from charge to discharge for each pulse |
||
|
End Condition |
Voltage、Relative Time |
||
DCIR |
Support for the calculation of the point of the DCIR |
|||
Cycle |
Cycles |
65535 |
||
|
Steps |
254 |
||
|
Nested Function |
Max three levels of loops |
||
Protective Function |
Software |
● Power-off data protection |
||
|
|
● Off-line Operating |
||
|
|
● User-defined safety(upper and lower)tolerance of current, voltage and delay time |
||
Channel Features |
Independent pairs of closed loop for constant current source and constant voltage source |
|||
Channels |
Independent control |
|||
Detection and Sampling |
4-wire Connecting |
|||
Noise Density |
<85dB |
|||
Data Management |
MYSQL Database |
|||
Communication Means |
TCP/IP Protocol |
|||
Export Formats |
EXCEL2003/2010, TXT, Graph |
|||
Communication Interface |
Ethernet Port |
|||
Number of Channels Per Cabinet |
8 |
|||
Operating Environment |
||||
Description |
Product Specification |
|||
Operating Temperature |
0℃~40℃ |
|||
Storage Temperature |
-10℃~50℃ |
|||
Operating Humidity |
≤70% RH |
|||
Storage Humidity |
≤80% RH |
|||
Description |
Product Specification |
|||
Battery Holder |
Universal Holder |
|||
Holder Picture |
|
|||
|
Picture for reference, please confirm the actual product |
|||
Dimensions (W*D*H)(mm) |
3U(19),480*330*130 |
Need help? Contact us!