BTS-9004-5V5A For Material Battery Research Tester Cutting-edge Technology-4channels

NewareBatteryTester-BTS9004-5V5A

This is BTS-9004-5V5A  Technology Specification

Description

Specification

AC Input

AC 220V +10% / -20%, 50Hz;(AC 110V, 60Hz can be customized)

Resolution

AD:16bit;DA:16bit

Impedance input

≥ 500MΩ 

Input power

250 w

Channel Feature

Independent pairs of closed loops for constant current source and constant voltage

source

Channel control mode

Independent control

Voltage

Measuring Range

Charge:0.7V~5V;Discharge:0.7V~5V

Discharge Min Voltage

0.7 V(Within 0.5 meter)

Accuracy

± 0.02%  of  FS

Stability

±0.005% of  FS

Current

Measuring Range

Range1:  0.1uA---150uA   

Range2:140uA---5mA

Range3:4.5mA---150mA

Range4:  140mA---5A

Accuracy

± 0.02%  of  FS

Range1:  ± 30nA

Range2:± 1uA

Range3:± 30uA

Range4:  ± 1mA

Stability

±0.005% of  FS

Power

Max Output Power Per

Channel

25W

Stability

± 0.01%  of  FS

Time

Rise Time

<= 100μS (10% to 90% or 90% to 10%);

Step Time Range

>=10ms

Data

acquisition

Intervals

Time△t:>=1ms

Voltage△U:>= 1mV

Current△I:>= 100nA

Frequency

1000Hz

Charge

Charge Mode

CC, CCCV, CV, CP, CR

End Conditions

Voltage, Current, △t, Capacity, Energy, Power

Discharge

Discharge Mode

CC, CP, CR, Pulse

 

End Conditions

Voltage, Current, △t, Capacity

Pulse

Charge

CC, CP

Discharge

CC, CP

Min. pulse width

400μs

Pulses counts

Up to 16 changes in each pulse

End conditions

Voltage, △t

DCIR

Can be calculated by software

Cycle

Max cycles

1~65535

Max steps in each cycle

255

Max cycle nest

4

Protection

Safety protection

l Power-off data protection

l Off-line operation mode

l User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.;

Data acquisition method

Kelvin connection

Database

MySQL

Communication

TCP/IP(100M Ethernet)

Data export

EXCEL2003,2010、TXT

Communication Interface

Ethernet port

Channels

4

Dimensions

W*D*H:443*615*125(mm)

Clamps

204 Air-plug, Polymer or alligator available

Operating system

Windows 7/ Windows 10

Operation and storage environment requirement

Description

Specification

Operation environment temperature

0℃~40℃ (When the temperature is 25±10℃, the accuracy error caused by temperature change is less than50ppm /℃)

Storage environment temperature

0~60℃

Operation environment humidity

≤70% RH(no moisture condensation)

Storage environment humidity

≤80% RH(no moisture condensation)

 

9004-5V5A-Neware-Battery-Testing-System bts_9000_img3-Neware Battery Testing System

 

                  

Read 2743 times