Displaying items by tag: battery material research

Tuesday, 13 September 2016 15:37

BTSDA only shows sectional battery test data?

A question about BTSDA comes from one of our customers.

I am using BTS TestControl 5.3.0013 (2010.6.2) with an 8 channel battery tester, model BTS-3008-5V10mA.
When I run a cell, it collects the data and shows every cycle, but after the data collection completes, the first eight cycles are missing (the data file starts with cycle #9).
How can I prevent this from happening?

Published in BTS-neware-useful docs
Tuesday, 13 September 2016 15:30

Operate BTS channels in a batch

Some customers asked us how to operate BTS channels together, such as how to start up tests together and how to export data all together.

In fact, it's easy. Please refer to the following pictures.

Step 1: In the main working area, you can use CTRl+A to select all the channels, or you can press the CTRL and click the channels you want to operate. If there's a yellow border around the channels, it means the channels were selected.

Published in BTS-neware-useful docs
Monday, 29 August 2016 16:11

IGBT-7000

BTS 7000 - High Voltage Battery Testing System for Module&Pack

HPPC, Capacity, Cycle Life, Over-charge, Over-discharge

CAN Bus Supported to Acquire Data from BMS (Battery Management System)
Up to 800kVA
0.2% Full-scale Accuracy for Current & Voltage
<=50ms Response Time
1Hz Data Acquisition Frequency, 10Hz Optional
Return Discharging Energy Back to Electrical Grid

Published in IGBT-7000
Monday, 29 August 2016 16:02

BTS-BVIR

BVIR - Portable Voltage & AC Resistance Meter

Voltage, AC Resistance as Defined by IEC Standards

Portable
AC Resistance and Voltage
4-Wire (Kelvin) Connections
Built-in Rechargeable Li-ion Battery
Easy to Calibrate
USB Interface
Storage for Up to 100,000 readings
Limit testing with pass/fail signals

 

Published in BTS-BVIR
Monday, 29 August 2016 16:09

BTS-8000

BTS 8000 - Electric Vehicle Battery Drive Cycle Testing System

Drive Cycle Simulation, HPPC, Capacity, Cycle Life Tests

Multi-current Ranges to Deliver Accurate Output
<=20ms Response Time to Meet Rapidly Changing Power Requirements
0.1% Full-scale Accuracy for Current & Voltage
10Hz Data Acquisition Frequency, 100Hz Optional
500ms Minimum Pulse Width
More Than 1 Million Records Can Be Processed

Published in BTS-8000
Friday, 01 April 2016 16:47

BTS-3000

BTS3000 is based on Neware 3rd generation test equipment. It's designed for cell, module formation, capacity and cycle life test, its output range is from 0V to 110V. BTS3000-5V3A/5V6A/10V3A are the star products of BTS3000 series, these low current products work extremely stable and accurate, some of these products worked continuously for more than 6 years in labs or universities.

In 2006, the 1st high-power equipment BTS3000-5V1000A, BTS3000-60V300A were developed successfully and introduced into domestic market as well as overseas market, their high-performance has been qualified by the market through out the years. It is reliable and time-tested for battery capacity grading and performance testing solutions.

BTS3000 is now the most popular type in the battery testing field, and it serves for research institutes, universities and battery manufacturers all around the world.

 

1.Market-proven Testing System

2.Plug & Play

3.0.1% Full-scale Accuracy for Current & Voltage

4.1Hz Data Acquisition Frequency

5.Multi Testing Modes Supported

Published in BTS-3000
Thursday, 31 March 2016 09:12

BTS-4000

BTS 4000 entered into market in the year of 2008. Now it is one of the most successful and most popular battery testing system in China. Thousands of battery manufacturers, battery research institutes and laboratories use it as their primary testing partner for their various testing activities.

BTS4000 is based on Neware 4th-generation testing system, and was introduced into the market in 2008. It's the upgrade version of the most popular battery test equipment series of BTS3000.

BTS4000 applies all the applications of BTS3000, plus EV battery pulse test, HPPC test and DCIR (direct current internal resistance) test.
Comparing with BTS3000, BTS4000 greatly improved the hardware response time, data acquisition frequency and result accuracy.

BTS4000 is the perfect test system in Neware's line of high quality, dependable test systems.

BTS4000 can be configured with multi-current range channels, which have a current control range of 0A to 3000A. These multi-current range channels can be configured for voltage ranges of 0V to 110V. The accuracy for current and voltage on these channels is ± 0.05% FS.

BTS4000 is now widely used by research institutes, colleges and universities and EV battery manufacturers all around our country. 

 

1.Resolution: AD: 16bit; DA: 16bit;

2.Accuracy : 0.05% FS*;

3.Response Time: ≤10ms (Current in the range 10%~90% FS);

4.Output Power: Max. 21kVA (user-definable);

4.Data Acquisition Frequency: 10Hz / 100Hz Optional;

5.Minimum Pulse Width: 500ms.

 

We have many many types for battery tester.

BTS-5V10mA;BTS-5V20mA;BTS-5V50mA;BTS-5V0.1A;BTS-5V3A;BTS-5V6A...

Published in BTS-4000
Thursday, 31 March 2016 09:16

BTS-9000

BTS9000 is based on Neware 6th-generation testing system. It's designed for battery material research, high-precision tests, pulse charge/discharge tests, DCIR test, and cycle life test. 

As the most cutting-edge equipment for battery material research, BTS9000 comes with extremely high accuracy(±0.02% of FS), amazing hardware response speed(≤100μs), wide range of applications, high-speed testing data acquisition and many other industry-proven characteristics, it's your ultimate choice for battery material research!

It characterized with a data acquisition frequency up to 1000Hz, an accuracy of 0.02% FS and a minimum pulse width of 400us (microsecond) which can be utilized for GSM or some other rapid pulse tests. Comes to the pulse tests, BTS9000 supports GSM(Global System for Mobile Communications), GPRS(General Packet Radio Service), CDMA-standby, CDMA-talk(Code Division Multiple Access), IDEN(Integrated Digital Enhanced Networks), etc.

 

1.Resolution: AD: 16bit; DA: 16bit;

2.Accuracy : 0.02% FS;

3.Response Time: ≤100us (Current in the range 10%~90% FS);

4.Data Acquisition Frequency: 1000Hz;

5.Minimum Pulse Width: 400us;

6.Voltage Range: 5V;

7.Current Ranges: Range 1: 160uA ± 32nA

                                  Range 2: 5mA ± 1uA

                                  Range 3: 160mA ± 32uA

                                  Range 4: 5000mA ± 1mA

Published in BTS-9000