More Focused, More Professional!

BTS-4000 Series 5V6A/ 5V12A Battery Tester

BTS-4000 series entered into market in the year of  2008. Now it is one of the most successful and most popular battery testing system in China and World. Thousands of battery manufacturers, battery research institutes and laboratories use it as their primary testing partner for their various testing activities.

Due to the rapid data acquisition frequency, BTS-4000 could be applied to super capacitor or EDLC (Electronic Double Layer Capacitor) test. Through our advanced software, the capacitance, DCIR(Direct Current Internal Resistance) could be easily calculated.

Accuracy

0.05%FS

Min. Pulse Width

500ms

Data Acquisition Frequency

10Hz/ 100Hz

DCIR

DCIR =△V/△I

Response Time

≤1ms

Multi Range

Triple Range

Born for Test

Specialized in testing 18650/26650/21700 Cylindrical Battery, Pouch Battery, Super Capacitor, etc
neware_battery_testing_system-5V6A-18650_battery_test
What's the 5V6A/ 5V12A battery tester's range?
5V6A
Range 1: 100mA
Range 2: 3A
Range 3: 6A

5V12A
Range 1: 1A
Range 2: 6A
Range 3: 12A
battery_testing_system_5V6A_02-neware_battery_tester

How to understand the triple range for Neware battery tester?

If you have neware 8 channels 5V6A battery tester with triple range.There will be triple range as below:
Range1: 0.5mA~100mA; Range2: 100mA~3A; Range3: 3A~6A.
Example: Using 50mA current to charge/discharge, the actually current should not be 50mA, it should has deviation value base on the range. If you have older 5V6A tester which has single range, so the output current will be 47mA~53mA. It has 3mA deviation value (3mA=6000mA*0.05%); If you have triple range 5V6A battery tester, so the output current will be 49.95mA~50.05mA.(The 50mA current output in the first range). It has 0.05mA deviation value (0.05mA=100mA*100mA). It highly improve the accuracy when you set different current.

The same with 5V12A or other multi range Neware battery tester.

How to understand the minimum discharge voltage for Neware battery tester?

As to Standard model for 5V6A/ 5V12A Neware Battery Tester, they has standard minimum discharge voltage as below:

5V6A: 1.0V (by using cylindrical clamp); 1.5V (with 2.0m length of testing cable)
5V12A: 2.0V (by using cylindrical clamp); 2.5V (with 2.0m length of testing cable)

Need lower minimum discharge voltage? Don't worry, Neware still can do this. Neware special power supply to support down to 0V~ 

How to understand the fixture of Neware battery tester?

Neware offer various different clamps to meet the different batteries, so our user can easilier to connect your battery and focus on battery testing.
As to 5V6A & 5V12A Neware battery tester, they have same clamps for cylindrical clamps, air-plug(connect aligator clamps or polymer clamps). The cylindrical clamp has adjustable height. You just use the straight screwdriver to adjust height, even use a coin. Wonderful, right?
Various types of batteries to be test

Different clamps can be supported.

5V6A_clamps-neware_battery_tester_cylindrical battery
5V6A_clamps-neware_battery_tester_pouch battery
Coin cell clamps
Cylindrical holder
Pouch Clamps
Alligator Clamps
Ring nose connector
Easy and convenient to check testing data, help you analysis data quickly!
(Voltage, Current, Capacity, DCIR, HPPC, Cycle Life, etc. )
Neware-BTS-DA-Interface-Setting
Not only the cylindrical battery can be test, but also Neware tester can test the pouch battery.
Neware-Software-Step-Setting-Interface
neware-battery-testing-system-5V6A-dimension-neware_battery_tester
Special design fan, to make sure all tests are good. Prevent over high temperature.
battery_testing_system_5V6A-2-neware_battery_tester
battery_testing_system_5V6A_03-neware_battery_tester
battery_testing_system_5V6A-3-neware_battery_tester

CT-4008T-5V6A-S1

5V6A-triple_range-neware_battery_tester

CT-4008T-5V12A-S1

5V6A-triple_range-neware_battery_tester

Neware Tester Running Test on Site

4008T-5V6A_Pouch_cell_tester-Neware_Battery_Testing_System-Tester-1
4008T-5V6A_Pouch_cell_tester-Neware_Battery_Testing_System-Tester-5
4008T-5V6A-Cylindrical-18650-21700-26650-Cell-Tester-Neware_Battery_Testing_System-Tester-3
4008T-5V6A_Pouch_cell_tester-Neware_Battery_Testing_System-Tester-2
4008T-5V6A_Pouch_cell_tester-Neware_Battery_Testing_System-Tester-6
4008T-5V6A-Cylindrical-18650-21700-26650-Cell-Tester-Neware_Battery_Testing_System-Tester-4
4008T-5V6A_Pouch_cell_tester-Neware_Battery_Testing_System-Tester-3
4008T-5V6A-Cylindrical-18650-21700-26650-Cell-Tester-Neware_Battery_Testing_System-Tester-1
4008T-5V6A-Cylindrical-18650-21700-26650-Cell-Tester-Neware_Battery_Testing_System-Tester-5
4008T-5V6A_Pouch_cell_tester-Neware_Battery_Testing_System-Tester-4
4008T-5V6A-Cylindrical-18650-21700-26650-Cell-Tester-Neware_Battery_Testing_System-Tester-2